IT fleet

A fleet assessment adds the equipment present over a period, its allocated manufacturing impact and its electricity consumption. The physical inventory forms the basis: a virtual machine is not an additional device.

Prepare the data​

InputWhere to find itWhat to check
Device count and modelInventory, CMDBPresence over the period, shared equipment
Manufacture per deviceProduct LCA or documented modelCovered phases and indicators
LifetimeReplacement recordsObserved duration or explicit assumption
Annual electricityMetering or power × timeActive, standby and off states

For each equipment family:

  • allocated manufacture = count × manufacture per device × period / lifetime.
  • electricity = count × annual energy per device × period.
  • use-phase impact = electricity × country electricity factor.

Detailed inventory and allocation method​

The inventory describes family, quantity, use location, commissioning date, lifetime and energy data. Each group contains devices with compatible factors. Product-specific data may replace a family average after checking included phases and units.

For a period TT in years and groups ii:

Ifleet=∑iqi(MiTiLi+EiTifi)I_{fleet}=\sum_i q_i\left(M_i\frac{T_i}{L_i}+E_iT_i f_i\right)

qiq_i is quantity, MiM_i manufacture/device, LiL_i lifetime, EiE_i annual energy and TiT_i time present in the period. The simulator assumes every group is present for the same TT; different dates require separate inventories.

SituationTreatment
Device introduced during the yearProrate presence and energy or use measured consumption
Stored or standby deviceManufacturing remains allocated; energy depends on actual state
Refurbished deviceExplicit first life, refurbishment and transfer convention; manufacture is not assumed zero
External displaySeparate contribution only when excluded from the workstation factor
Shared server or networkOne allocation among benefiting services

Operating states and replacement​

Without annual measurements, E=∑sWshs/1000E=\sum_s W_s h_s/1000 adds active, standby and off-state consumption. Durations cover the whole period; powers describe each state rather than just nominal power.

Consumption by device operating state
Durations over a fictitious 24-hour day
Active8 h
Standby8 h
Off8 h
50 W2 W0.5 W
400 Wh16 Wh4 Wh
420 Whequivalent to 0.420 kWh over the day

Fictitious power values. The device remains plugged in when off. Segment widths represent time, not energy consumed.

Longer lifetime reduces annualized manufacture in attributional accounting. It does not itself measure physically avoided production. A replacement assessment covers an equal service period, including consumption, repair and potential performance differences.

This allocation differs from annual purchasing accounts, which assign manufacture at acquisition. They answer different questions and should not be added together.

Factor boundaries determine the treatment of end of life, transport and maintenance. Missing data remains visible. Indicators have distinct interpretations: manufacturing and use contributions vary by electricity mix and impact category.

From the equipment fleet to the information system​

The equipment fleet is one part of the information system. The information-system PCR assesses an organisation's system over one year, including outsourced services and support resources. It includes travel by people contributing to the system. Customer-facing services require a separate assessment: their boundary differs from the internal information system.1

The simulator remains a fleet example. Widening the study includes cloud, software, networks and support in the inventory, with overlaps removed for equipment already counted. Exclusions specific to the information-system PCR do not automatically apply to an application or web service.

Shared devices and reuse​

The information-system PCR proposes professional-use shares of 57% for BYOD and 85% for COPE; the latter is described as an incentive convention. These are not universal physical measurements and do not become D4B defaults. The professional-use share and its source form part of the documented assumptions.

For refurbished equipment, a documented first life can contribute to total lifetime. A possible future life needs supporting evidence: assumed reuse is insufficient to reduce allocated manufacturing.

Complete the boundary​

Server room cooling is excluded. The Hosting case covers that contribution, with each server counted once. For equipment present for six months, the assessment period or allocation share reflects that presence. Storage without use does not remove its allocated manufacture.

The result is framed by boundary and functional unit, allocation and double counting.

Electricity factors come from the D4B 2025 snapshot2. Prefilled activity and hosting values are exercise assumptions. Factors and conventions are available below the simulator.

Increasing laptop lifetime decreases annual allocated manufacture; electricity stays unchanged if usage is identical. This is a lifetime allocation calculation. It does not, by itself, measure emissions avoided by postponing a purchase.

40 kg CO₂e/year of allocated manufacturing
Example: 200 kg CO₂e of equipment manufacturing allocated over its lifetime. Use excluded; this calculation does not measure avoided emissions.

Interactive example​

This example applies the calculations and limitations described above.

The simulator starts with a fictional business: 50 laptops, 30 displays, 50 smartphones, three switches and two servers. Manufacturing values are exercise inputs, not recommended factors.

Ex: 50 laptops with 200 kg CO₂e manufacturing impact and a five-year lifetime account for 50 × 200 / 5 = 2,000 kg CO₂e/year. At 70.4 kWh per laptop per year, electricity consumption is 3,520 kWh/year.

With the prefilled inventory and the France 2025 factor, the subtotal is 4,133.67 kg CO₂e/year: 3,795 kg allocated manufacture and 338.67 kg electricity.

Example inputs
Equipment factors
Equipment factors
Equipment factors
Equipment factors
Equipment factors
Adjust assumptions
Calculated subtotal4,134 kg CO₂e
4,134 kg CO₂e / year

Not assessed: Cooling and equipment absent from the inventory.

Result and activity breakdown

Contributionkg CO₂e
Allocated manufacture3,795
Use-phase electricity · 10,610 kWh338.7
  • Equipment energy : 10,610 kWh

Prefilled activity and hosting values are example assumptions. The result covers climate impact; unassessed contributions remain identified.

Simulator factors and conventions

Electricity: D4B 2025 national averages. Use country does not change manufacture. Network factors remain unknown until supplied; they must cover the full path, manufacture and operation included. In this illustration, the distance from the D4B per-GB·km model is incorporated upstream into the per-GB route factor.

Annual energy per device, all power states included. For hosting, enter IT energy before PUE. Prefilled inventory profiles are assumptions from this page’s worked example.

Footnotes​

  1. ADEME, RCP des systèmes d’information, mise à jour novembre 2024, p. 8–14. ↩

  2. Digital4Better, D4B 2025 snapshot. Snapshot 77cae4a, 2025 data; reviewed 16 October 2026. ↩