Assumptions and defaults register

This page centralizes shared numerical assumptions and conventions. It is the single reference register for defaults. A default repeated across chapters must appear here.1

Usage rules​

  • This register records assumptions shared by multiple chapters.
  • Local pages may repeat a value without creating a competing register.
  • Associate entries with a source, date and application context.
  • Justify revisions; see Time and versioning.

Shared assumptions​

General framework​

AssumptionValue/conventionSourceApplication
Methodological perspectiveAttributional by defaultDigital4Better methodologyAll assessments; consequential variants discussed where relevant
Environmental indicatorsNine midpoints plus electricity consumptionD4B convention; see IndicatorsAll assessments, subject to available compatible factors
Source hierarchyMeasurement → primary → provider → literature → generic estimateSource hierarchySelection of assessment data

Electricity and energy​

AssumptionValue/conventionSourceApplication
Electricity factorsdigital4better/data preferreddata/factor/*, data/energy/*Most robust compatible time resolution; monthly where available, annual otherwise 2
Electricity mixConsumption-based, including imports/exportsdigital4better/dataOperational impacts; see the cloud convention for the renewable share
Generation technologiesCoal, gas, other fossil, wind, solar, bioenergy, hydro, other renewable, nuclearUNECE; Energy Conversion and Management, 2022Country-factor calculation

Datacenters and infrastructure​

AssumptionValue/conventionSourceApplication
Default PUE1.58, historical scenarioHistorical Uptime Institute reference; not a verified current meanWhen actual PUE is unknown 3
RAM power0.000392 kW/GBCloud Jewels / Cloud Carbon FootprintServer component estimate 4
SSD power1.2 × 10⁻³ kW/TBCloud Jewels / Cloud Carbon FootprintServer component estimate
HDD power0.65 × 10⁻³ kW/TBCloud Jewels / Cloud Carbon FootprintServer component estimate
Inter-datacenter networkScenario: 0.001 kWh/GBCloud Carbon Footprint Appendix I; inconsistent Gb/GB notation in prose requires clarificationDoes not automatically cover LAN or user access
Server lifetime for reference VM factorsFive yearsNegaOctet / Base EmpreinteEmbodied VM factors

Networks​

AssumptionValue/conventionSourceApplication
D4B network factorsPer-GB·km factors, or per-byte·km before conversionD4B convention still in use; network modelVolume × estimated distance × factor; per-GB illustrations incorporate the route upstream
Within-country distanceEstimated country radius: r=A/πr=\sqrt{A/\pi}Country-area data and D4B conventionApproximation of national segments
Between-country distanceGreat-circle route between centroidsCentroid data and spherical geometryApproximation of international segments
Home-router traffic220 GB/monthHistorical ICT 2020 and ADEME/ARCEP 2022 contextRouter allocation within fixed-network factors
CDN cache hit rate70–90% sensitivity scenarios; historical web example 95%Unmeasured D4B assumptionsReduction of traffic after the CDN, not the whole user path

Component embodied models​

ComponentEquationGWP coefficientsSource/status
Historical CPU, not complete GPU cardI=(diemm2Cdie+Cbase)FnodeFpkgI=(die_{mm^2}C_{die}+C_{base})F_{node}F_{pkg}Cdie=0.0197C_{die}=0.0197 kg CO₂e/mm²; Cbase=9.14C_{base}=9.14 kg CO₂eHistorical UBA/Boavizta coefficients; node/package factors are D4B scenarios
RAMI=((capacityGB/density)Cdie+Cbase)FpkgI=((capacity_{GB}/density)C_{die}+C_{base})F_{pkg} per moduleCdie=2.20C_{die}=2.20 kg CO₂e/cm²; Cbase=5.22C_{base}=5.22 kg CO₂e; scenario density 0.625 GB/cm²UBA historical model; density is not universal
SSDI=(capacityGB/densityNAND)Cdie+CbaseI=(capacity_{GB}/density_{NAND})C_{die}+C_{base} per driveCdie=2.20C_{die}=2.20 kg CO₂e/cm²; Cbase=6.34C_{base}=6.34 kg CO₂e; scenario density 48.5 GB/cm²UBA historical model; density is technology-dependent
HDDI=31.11I=31.11 kg CO₂e per driveGeneric scenarioGreen Cloud Computing, UBA, 2021
DisplayI=areacm2Ctechnology+CbaseI=area_{cm^2}C_{technology}+C_{base}LCD 0.07 kg CO₂e/cm²; OLED 0.12; base 3.0 kgD4B educational assumption; calibration not established
BatteryI=capacitykWhFchemistryI=capacity_{kWh}F_{chemistry}LCO 75; NMC 65; LFP 50 kg CO₂e/kWhD4B scenarios, not validated by the cited battery publications

Semiconductor multicriteria reconstruction​

Status: not validated on 16 October 2026. Previous AP, WU, PM, IR and ADPe values reconstructed from an Intel inventory are no longer defaults. Reintroduction requires elementary flows, units and compartments, versioned LCIA factors, surface/yield rules and a reproducible calculation. Replaced values remain in refactoring archives.

CPU, RAM and SSD models retain explicitly sourced historical coefficients. Physical water cannot be added to characterized water impacts in m³ equivalents.

Manufacturing-country scenarios​

These countries are sensitivity scenarios, not known locations for every component. Aggregate manufacturing factors cannot be relocated by multiplying by an electricity-mix ratio. Substitution requires an inventory separating electricity from other processes.

ComponentScenario countryStatus
Advanced logicTaiwanD4B assumption; actual fabrication site remains to be established
RAM and NANDSouth KoreaD4B assumption; actual fabrication site remains to be established
Assembly, displays, batteries, PCBsChinaD4B assumption; actual manufacturing site remains to be established

CPU/GPU process-node scenarios, FnodeF_{node}​

These are sensitivity assumptions without an identified reproducible imec calibration. They do not demonstrate the environmental performance of a chip generation.

NodeFnodeF_{node}Status
28 nm1.0D4B reference scenario
14 nm1.2Exploratory D4B assumption
10 nm1.4Exploratory D4B assumption
7 nm1.8Exploratory D4B assumption
5 nm2.2Exploratory D4B assumption
4 nm2.5Exploratory D4B assumption
3 nm2.8Exploratory D4B assumption

Equipment and lifetime​

AssumptionValue/conventionSourceApplication
Preferred approachComponent reconstruction where justified by data; documented equipment factors as an alternativeDigital4Better methodologyRepresentativeness takes precedence over apparent detail
Missing dataMeasurement → primary → provider → literature → generic estimateSource hierarchyMissing parameters
Lifetime adjustmentIFemb=TIFemb×TL/RLIF_{emb}=TIF_{emb}\times TL/RLD4B conventionAdjustment of a time-normalized reference factor when actual and reference lifetimes differ
vCPURelationship to hardware threads depends on offering and architectureD4B allocation conventionExplicit mapping required for component allocation

Current exclusions​

Excluded topicReasonFuture work
VideoconferencingOutside this iterationPossible later use case
Video streamingOutside this iterationPossible later use case
IoT / embedded systemsOutside this iterationPossible later use case

Historical web-service scenarios​

The 69/34 seconds per view and 59% mobile values come from historical references in the web chapter (2023). The historical score uses a different convention: 20 seconds and 58% mobile. None is a guaranteed current average. The internal view-distribution model and conversion of one user-second to one vCPU-second are not validated out of sample and do not replace service measurements. December 2023 tables remain for traceability, with method and unit qualifications.

Simulators and validation snapshot ; 16 October 2026​

ParameterValue/ruleStatus and provenance
Simulator electricity2025 annual averages, 15 countries in local fileD4B commit 77cae4a5, data/factor/country-yearly.csv; local selection in src/data/electricity-factors.json
REFNo automatic reduction of reference mixSeparate sensitivity only; SCI compatibility requires verification
WUEL/kWh IT × IT energyPhysical direct water; distinct from characterized WU
IRNumerical total withheld from equipment simulatorResolve historical kg/kBq inconsistency from upstream inventories
16:9 displayArea = diagonal² × 2.54² × 144/337Exact geometry; diagonal in inches, area in cm²
AI compute2P per input/output token; 6P per training token, active PDense-layer approximation; attention, memory and communication require calibration
AI fine-tuningTraining-scale compute scenarioNo saving inferred from LoRA trainable fraction alone
AI MFU / initial PUE0.4 / 1.2Scenario assumptions, not provider measurements
AI lifetime5 × 365.25 × 24 hoursSimulator allocation by active time; reserved-time allocation remains separate
AI cacheResidual cost α = 0.1; reuse 0–100%Assumption applied before time/energy; memory overhead not measured
AI hardwareComponent power and manufacturing in src/data/ai-hardware-profiles.jsonScenarios, not certified LCAs; B300 host memory corrected to 2 TB
BatteryForm: LCO 75, NMC 65, LFP 50; documented NMC 811 scenario: 60 kg CO₂e/kWhScenarios; water/ADPe withheld without traceable factors

Local capacity, lifetime, load, density and composition presets are visible in each form. They are editable examples, not equipment recommendations. Process and packaging coefficients remain exploratory until calibration is published.

Dataset gaps​

Further evidence is needed for:

  • explicit critical-material inventories.
  • upstream semiconductor modeling conventions.
  • consistent multicriteria factors for some supporting layers.
  • embodied LAN factors in the system approach.

Assumptions and limitations​

  • The register is being consolidated and must be updated when a shared assumption changes.
  • Defaults are working conventions, not universal facts. Better-matched evidence replaces them when available.
  • An unavailable factor is not zero. An exploratory coefficient is not a measured value.

Background for data selection, not validation of default values.

Component illustration parameters​

The shared register is versioned d4b-components-illustration-2026.10.19. It separates historical coefficients from the assumptions below. Centralisation makes examples consistent; it does not establish scientific calibration.

ParameterExercise valueScope
DDR5 RAMDensity 1 GB/cm²; packaging 1.1Same formula for RAM, terminal and server examples
HBM2e / HBM3Densities 0.5 / 0.8; packaging 3 / 3.5Exploratory scenarios; interposer counted once
Server memory modulesAssumed 32 GB per moduleCount rounded up; total capacity preserved
Server drivesAssumed 2 TB SSD, 4 TB HDDSame rule; per-drive constants follow drive count
Structural residualSmartphone 4, tablet 5, laptop 8, desktop 12, server 50 kg CO₂eAssumptions without overlap with inventoried components
Device power50% CPU TDP + display + 2 W auxiliaryExercise model, not measured fleet-average power
Server powerCPU/GPU TDP + RAM + storage + 50 W auxiliaryConstant-power scenario before PUE
Computer mix60% laptop, 40% desktop with displayActive-time weighting, not audience statistics
Mobile mix95% smartphone, 5% tabletSame convention
Device profile allocationCalculated manufacture / lifetime / 8,760 h/yearPer-second factor is derived, not copied from old flat factors

Configurations also describe capacity, component count, display and battery. Unknown properties of actual equipment remain assumptions or unassessed items. Old VM and device factors are historical references, no longer the target model.

Service device profiles use 365 days per year for the per-second factor. Component examples and AI use 365.25 days for annual energy or time allocation. These conventions remain explicit; harmonising them would change results and require a new version.

Footnotes​

  1. digital4better/data. Methodological corpus. ADEME Base Empreinte. Digital4Better data catalogue, snapshot 77cae4a. References and scope: Sources and corpus. ↩

  2. Digital4Better, digital4better/dataEvolving catalogue; pin a commit for reproducible factors. ↩

  3. Uptime Institute historical PUE discussion ↩

  4. Cloud Carbon Footprint Online documentation, unpinned version. ↩

  5. Digital4Better, D4B commit 77cae4a. Snapshot 77cae4a, 2025 data; reviewed 16 October 2026. ↩