Storage
Storage technologies have different manufacturing and operating profiles. The historical Boavizta model gives 51.70 kg CO₂ eq. for a 1 TB SSD at an assumed density of 48.5 GB/cm², compared with a 31.11 kg fixed HDD estimate. These are different models from literature averages per GB. A comparison covers performance, lifetime and measured operating behaviour as well as capacity.
Physical contributions
SSD
An SSD contains NAND flash, control electronics and a board or other assembly. Fabrication includes semiconductor processes; layer counts and die organisation depend on generation.
HDD
An HDD combines magnetic platters, motors, heads, electronics and mechanical assembly. A fixed impact per drive is a historical simplification, not evidence that real manufacturing is independent of capacity, platter count or electronics.
Parametric models
SSD die-area model
is capacity per drive in GB, is GB/cm², and is drive count. The base covers the model's fixed assembly contribution; inspect its boundary before adding other parts.
| Indicator | Die coefficient per cm² | Base per drive | Unit |
|---|---|---|---|
| GWP | 2.20 | 6.34 | kg CO₂ eq. |
| ADP | 6.30E-05 | 5.63E-04 | kg Sb eq. |
| Primary energy | 27.30 | 73.98 | MJ |
See Boavizta SSD documentation1. The 48.5 GB/cm² density is a historical model assumption, not a demonstrated average for every NAND generation. Density alone does not capture changing process complexity, yields and packaging.2
HDD fixed estimate
| Indicator | Per-drive value | Unit |
|---|---|---|
| GWP | 31.11 | kg CO₂ eq. |
| ADP | 2.50E-04 | kg Sb eq. |
| Primary energy | 276.00 | MJ |
Source: the historical Boavizta HDD model3, based on Green Cloud Computing. Combining ADP with another source's ADPe requires method compatibility. Unsupported reconstructed AP/PM coefficients are not retained as validated factors.
Storage Embodied Factor
Tannu and Nair's 2023 paper4 analyses 94 SSD and 24 HDD reports. Its capacity-based examples use 0.16 and approximately 0.02 kg CO₂ eq./GB respectively. These dataset averages do not establish universal technology ratios.
Five-year comparison and source inconsistency
The paper's table reports 56.9/183.9 kWh and 24.6/79.6 kg operational emissions for SSD/HDD. Those emissions imply about 0.433 kg/kWh, inconsistent with the text's stated 0.7 kg/kWh. Using the latter explicitly gives:
| Scenario | SSD, 1 TB | HDD, 1 TB |
|---|---|---|
| Embodied assumption | 160 kg CO₂ eq. | 20 kg CO₂ eq. |
| Five-year electricity | 56.9 kWh | 183.9 kWh |
| Recalculated operation at 0.7 kg/kWh | 39.83 kg CO₂ eq. | 128.73 kg CO₂ eq. |
| Recalculated total | 199.83 kg CO₂ eq. | 148.73 kg CO₂ eq. |
The ratio is 1.34, not 1.8. This does not prove HDD superiority for equivalent delivered performance. The per-TB power model below is separate and must not be mixed with this scenario's operating assumptions.5
Operational model
is physical storage in decimal TB. These are historical Cloud Carbon Footprint/Cloud Jewels estimates.
| Capacity | SSD power | HDD power |
|---|---|---|
| 1 TB | 1.2 W | 0.65 W |
| 4 TB | 4.8 W | 2.6 W |
| 16 TB | 19.2 W | 10.4 W |
Capacity and overhead
- RAID: mirroring needs two physical copies for a given usable capacity. With equal drives in RAID-5, parity occupies of raw capacity, while overhead relative to usable capacity is and raw/usable capacity is .
- Replication: three copies can triple physical capacity when the input is logical. The result depends on compression, deduplication, erasure coding and the supplier factor's existing boundary.
- PUE: apply site overhead to IT electricity only when not already included.
An inventory that already counts physical drives already includes redundancy.
Indicator coverage
| Indicator | Treatment |
|---|---|
| GWP | Historical SSD and HDD models, with configuration limitations |
| ADP / ADPe | Historical coefficients; LCIA compatibility required |
| Primary energy | Historical coefficients, distinct from electrical consumption |
| WU | Compatible characterised inventory needed; no universal water-per-area factor |
| AP, PM, toxicity | Aggregate inventories may include these without isolating the drive |
| IR | Manufacturing and use require compatible inventories and verified units |
The current interactive output presents GWP and electricity, not a complete multicriteria LCA.
Assumptions and limitations
The historical SSD model shares die coefficients with the RAM model. Density does not capture all process or packaging differences. A fixed HDD factor ignores differences such as platter count. Redundancy must be explicit. Capacity, endurance, throughput and latency must be compatible when comparing alternative storage services.